Kantech – Controller connection— Communication Failure – EntraPass – 8.10 – Software – Administration Guide EntraPass Corporate Edition Administration Guide prodname EntraPass vrm_version 8.10 doctype Administration Guide revised_modified 2019-05-26, RS-485 (COM2) for RS-485 communication between the KT-400 and RS-485 modules. SPI for communication with SPI modules. Note: You can connect a loop of KT-200 controllers on the RS-485 of the KT-400 if not mixed with other controllers ( Kantech KT-100, KT-300 and KT-400 ).

If there is a communication failure between EntraPass and the KT-400 , an alarm will be triggered in the EntraPass system. … supervised by the KT-400 . Multiple Communication Ports … Cable kit, Kantech /DSC PowerSeries Neo, RS-232 to 422 converter, connector and cable 1.8 m (6 ft).

If you are using KT400’s then it is always the locks shorting out the controllers, the KT400’s use wet lock supply directly off the controller, if there is a potential to ground anywhere in the…

Note: You can connect a loop of KT-200 controllers on the RS-485 of the KT-400 if not mixed with other controllers (KT-100, KT-300 and KT-400 ). Note: The 10/100Base-T (ETH2) , RS-485 (COM2) and USB 2.0 Host communication ports are to be used ONLY on, KT-400 Installation Manual DN1726 – Kantech, KT-400 Installation Manual DN1726 – Kantech, Communication issues with Kantech Entrapass Corp Edition …

Communication issues with Kantech Entrapass Corp Edition …

In the Delays section: . Heartbeat frequency (mm:ss): Enter the frequency to which you want the IP device to send a signal to the gateway to indicate it is online (00:15 to 10:00). Fail to report after (mm:ss): Enter the delay before acknowledging communication failure (01:30 to 59:59). Fail-soft delay on gateway communication failure (mm:ss): Enter the delay before the IP device will consider …

Required Wire: Ethernet communication (TCP or UDP) RS-485: 2 twisted pairs, #22AWG,unshielded, Ethernet CAT3 ; Compatible with Ethernet CAT5e cable, 10/16/2018  · 5 communications loop which shares a common ground. If your using KT300’s then the same problem exists. KT200’s i believe are form C relays for locks and dont suffer from this, th us why most people say they are rock solid, in all reality the 400’s instal led correctly will outlast any 200.

• Connect Kantech part number KT-ACPW-LED status indicator to the 16 VAC black terminals of the KT-400 • Use Kantech part number KT-BATT-12 battery, see Note . Note: Backup battery provides operation of up to 12 hours but has been tested for 4 hours per Section 33 of UL 294,, KT-400 Ethernet-Ready Four-Door Controller. KT-400 is an Ethernet-ready four-door controller that provides 128-bit AES encrypted communication with the EntraPass Security Software and is a highly secure solution for any security-conscious business.