Kantech – Controller connection Communication Failure – EntraPass – 8.10 – Software – Administration Guide EntraPass Corporate Edition Administration Guide prodname EntraPass vrm_version 8.10 doctype Administration Guide revised_modified 2019-05-26, RS-485 (COM2) for RS-485 communication between the KT-400 and RS-485 modules. SPI for communication with SPI modules. Note: You can connect a loop of KT-200 controllers on the RS-485 of the KT-400 if not mixed with other controllers ( Kantech KT-100, KT-300 and KT-400 ).
If there is a communication failure between EntraPass and the KT-400 , an alarm will be triggered in the EntraPass system. … supervised by the KT-400 . Multiple Communication Ports … Cable kit, Kantech /DSC PowerSeries Neo, RS-232 to 422 converter, connector and cable 1.8 m (6 ft).
If you are using KT400’s then it is always the locks shorting out the controllers, the KT400’s use wet lock supply directly off the controller, if there is a potential to ground anywhere in the…
Note: You can connect a loop of KT-200 controllers on the RS-485 of the KT-400 if not mixed with other controllers (KT-100, KT-300 and KT-400 ). Note: The 10/100Base-T (ETH2) , RS-485 (COM2) and USB 2.0 Host communication ports are to be used ONLY on, KT-400 Installation Manual DN1726 – Kantech, KT-400 Installation Manual DN1726 – Kantech, Communication issues with Kantech Entrapass Corp Edition …
Communication issues with Kantech Entrapass Corp Edition …
In the Delays section: . Heartbeat frequency (mm:ss): Enter the frequency to which you want the IP device to send a signal to the gateway to indicate it is online (00:15 to 10:00). Fail to report after (mm:ss): Enter the delay before acknowledging communication failure (01:30 to 59:59). Fail-soft delay on gateway communication failure (mm:ss): Enter the delay before the IP device will consider …
Required Wire: Ethernet communication (TCP or UDP) RS-485: 2 twisted pairs, #22AWG,unshielded, Ethernet CAT3 ; Compatible with Ethernet CAT5e cable, 10/16/2018 · 5 communications loop which shares a common ground. If your using KT300’s then the same problem exists. KT200’s i believe are form C relays for locks and dont suffer from this, th us why most people say they are rock solid, in all reality the 400’s instal led correctly will outlast any 200.
Connect Kantech part number KT-ACPW-LED status indicator to the 16 VAC black terminals of the KT-400 Use Kantech part number KT-BATT-12 battery, see Note . Note: Backup battery provides operation of up to 12 hours but has been tested for 4 hours per Section 33 of UL 294,, KT-400 Ethernet-Ready Four-Door Controller. KT-400 is an Ethernet-ready four-door controller that provides 128-bit AES encrypted communication with the EntraPass Security Software and is a highly secure solution for any security-conscious business.